American Journal of Environmental Protection

| Peer-Reviewed |

State of Play on the Physicochemical Quality of Waters Stored in Concrete Tank Buried Under Wet and Polluted Soil: The Case of the City of Pointe-Noire (CONGO)

Received: Nov. 30, 2018    Accepted: Dec. 19, 2018    Published: Jan. 10, 2019
Views:       Downloads:

Share This Article

Abstract

The problem of water supply from the public distribution network is still very acute in many cities in developing countries. The intermittent supply of water is forcing some households to build underground tanks of reinforced concrete to store domestic water. This work shows the problem of sustainability of water storage tanks made of concrete, in an aggressive environment but also especially the physicochemical quality of water stored in. The methodological approach chosen is based first of all on the physicochemical analysis of the water stored in these tanks. Indeed, the reliability of tanks, which reflected in their impermeability overlooked external environment, has a direct impact on the quality of stored water and therefore the use that is made daily. In this context, the results of the physicochemical measurements carried out, the comparison of the water coming out of the treatment plant of the National Water Distribution Company (SNDE), made it possible to highlight indices of pollution in the stored waters contained in the buried tanks.. Some samples of stored water, about 42.10%; which poses a public health problem. These results have clearly demonstrated the porous nature of the concrete chosen as the base material used for the construction of said tanks. Thus, anthropogenic pollution is evoked, which is confirmed by the high levels of physicochemical parameters measured in samples RE01, RE02, RE03, RE04, RE04, RE05, RE10, RE11 and RE12. In addition, 57.9% of these stored waters have low mineralization. These are acceptable as drinking water (RE06, RE07, RE08, RE09, RE13, RE14, RE15, RE16, RE17, RE18 and RE19). These waters identified as such must be subject to specific treatment and time monitoring. These results were obtained during dry season. During this period, there is drawdown of ground water. In rainy season, ground water is enhanced and exchanges are more important.

DOI 10.11648/j.ajep.20180706.13
Published in American Journal of Environmental Protection ( Volume 7, Issue 6, December 2018 )
Page(s) 84-98
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Underground Tanks, Water Storage, Diffusion, Pollutant, Reinforced Concrete, Porosity, Contamination

References
[1] Directives de qualité pour l’eau de boisson: 3e édition, vol. 1. Recommandation de l’Organisation Mondiale de la Santé (OMS), 2004.
[2] Directives de qualité pour l’eau de boisson: 4e édition, intégrant le 1er additif (Guidelines for drinking-water quality, 4th edition incorporating first addendum), Organisation Mondiale de la Santé (OMS), Genève, 2017.
[3] AESN (2006). Agence Seine de Normandie. Les enjeux de la gestion de l’eau. Rapport d’étude. Disponible en ligne sur: http//www.eau-seine-normandie.fr/fileadmin/ /AESN-COL= cours-4.1.pdf du 04/11/2014.
[4] Moukolo N. et Cheikh Becaye Gaye (2001), "Problèmes de contamination des nappes phréatiques par les rejets domestiques dans les métropoles d'Afrique noire - cas de la nappe de Brazzaville Congo", Unité de recherche sur les écosystèmes aquatiques - Brazzaville, 2001.
[5] E. O. Houssounou, M. Agassounon Djikpo Tchibozo, N. C. Kelome, E. W. Vissin, G. A. Mensah et E. Agbossou (2016). Pollution des eaux à usage domestiques dans les milieux urbains défavorisés des pays en développement: synthèse bibliographique. International Journal of Biological and Chemical Sciences Sci. (10) (5): 2392-2412, October 2016. ISSN 1997-342X (Online), ISSN 1991-8631 (Print).
[6] Dimane F., Haboubi K., Hanafi I., El Himri A., Aridaloussi K. (2017). Impact des facteurs de pollution sur la qualité des eaux de la zone aval de la vallée de l’Oued Nekor (Al-Hoceima, Maroc). European Scientific Journal, January 2017. ISSN: 1857-7881.
[7] Malanda N.1, Tathy C.2, Louzolo-Kimbembe P.3 Modeling of the Diffusion of polluant through Concrete Walls: Case of an Underground Water Tank in Wet Soil Un (1) article paru en 2015; ISSN: 1701-8285,37 (2) 1408-1415 http://recentscience.or.
[8] Brangeon Samantha (2015). La gestion des déchets des acteurs de l’aide. Étude de cas: Haïti. En ligne sur https://www.urd.org/IMG/pdf/rapportdechets du 22/10/2018 humanite-haiti.
[9] Dufour F. (2007). Contribution à la modélisation numérique de la fissuration des structures en béton avec prise en compte du fluage et estimation de la perméabilité mémoire d’habilitation à diriger les recherches. Spécialité génie-civil, école doctorale, mécanique, thermique et génie civil école centrale de Nantes: 2007, 89 pages.
[10] El Amri N., Sabbar M., Chakir H., Mangoub G. Détermination expérimentale de coefficient de diffusion des ions chlorures dans le béton armé. Faculté des Sciences techniques de Settat, Faculté des Sciences Ben M’sik, Casablanca, Maroc 2012.
[11] Chen, W. Études expérimentale de la perméabilité du béton sous conditions thermiques et hydriques variables. Thèse de doctorat – École Centrale de Lille, Génie-civil: 2011, 171 pages.
[12] Affes R. Relation microstructure – fissuration perméabilité dans les milieux granulaires cimentés. Thèse de doctorat en Sciences et techniques de Languedoc: Spécialité mécanique et génie civil: université Montpellier II: 2012. 143 pages.
[13] Liu J. Étude expérimentale de la perméabilité relative des matériaux cimentaires et simulation numérique du transfert d’eau dans le béton. thèse de Doctorat, Génie-civil: École Centrale de Lille: décembre 2011: 160 pages.
[14] Samba G. and Nganga D. (2011): Rainfall variability in Congo-Brazzaville. 1932-2007. Int. J. Climatol. Published online in wiley.
[15] IPCC (2007): IPCC Fourth assessment report: climate change 2007 (AR4), IPCC, Geneva, Switzerland.
[16] Nkounkou Tomadiatounga D., Mabiala B. and Moukandi Nkaya (2016). Hydrochemical characteristics of the groundwater AQ1 of the region from Pointe-Noire to Congo Brazzaville. Journal of geoscience and environment protection, 4, 95-109.
[17] Suk H. and Lee K. "Characterization of a ground water hydrochemical system through multivariate analysis: Clustering into ground water zones. Ground Water". vol. 37, pp. 358-366, 1999.
[18] Das N.e., "Physico-chemical characteristics of selected ground water samples of Ballapur city of Chandrapur District, Maharashitia. India", Int. Rest. 1. Environment Sci., vol. 2, no. II. pp. 96- 100, 2013. 40.
[19] Belkhiri L., Boudoukha A. and Mou ni L., "A multivariate Statistical Analysis or Groundwater Chemistry Data", lm. 1. Environ. Res., vol. 5, 110. 2, pp. 537-544, 2011.
[20] Belghiti Moulay L., Chahlaoui Adbelkader et Bengoumi Driss: «Caractéristiques physico-chimiques des eaux de certains puits utilisés comme source d’eau potable en milieu rural, dans la région de Meknès (Maroc). Revue science en liberté, édition Mersenne, vol. 5, N 130115, 2013.
[21] Matini L., Moutou J. M. et Kongo-Mantono M.S.: «Évaluation hydro-chimique des eaux souterraines en milieu urbain au Sud-Ouest de Brazzaville, Congo», Afrique Sciences, 05 (1), 2009, 82-98 ISSN: 1813-548x.
[22] Gbénonchi Mawassi Laukondoa Kolami, Damien Devault, Komla Sanda (2016. The contamination levels of water and sediment from lake Togo by the persistent organic polluants (Pops). American journal of environmental protection. Vol. 5, N° 2, 2016 pp. 20-28. DOI: 10.11648/j.ajep.20160502.11
[23] Malanda N., Matini L., Louzolo-Kimbembe P. Evaluation of physico-chemical quality of water stored in underground reinforced concrete tanks: case study of wetlands in Brazzaville (Congo). International Journal of Advanced. Research in engineering technology, 2014, vol. 5, n 10, pp. 34-44
[24] Malanda N., Louzolo-Kimbembe P., 2014: Survey on storage of water for domestic use in underground reinforced concrete tanks: the case of Brazzaville (Republic of Congo). Open Journal of civil engineering, 2014, 4, 13-22.
[25] Malanda Narcisse (2016): Problème de stockage de l’eau dans les réservoirs enterrés en béton. Modélisation de la diffusion non linéaire en milieu poreux. Presses académiques francophones (PAF), ISBN, 978-8416-3031.
[26] Desmettre, C (2011). Contribution à l’étude de la perméabilité du béton armé sous sollicitations statiques et cycliques. Thèse de doctorat (PhD), Département des génies civils, géologique et des mines. École polytechnique de Montréal, Canada 2011.
[27] Rastiello, G. Influence de la fissuration sur le transfert de fluide dans les structures en béton. Stratégies de modélisation probabiliste et étude expérimentale. Thèse de doctorat: université Paris Est: 2013, 169 pages.
[28] Wendy M.R., John M., Sharp Jr. (2013). Variability of groundwater nitrate concentration over time in arid basin aquifers: sources, mechanisms of transport, and implication of conceptual models. Environ earth Sci (013) 69: 2415-24 26. DOI 10.1007/S12665-012-2069-1.
[29] S. Guergazi, S. Achour (2005). Caractéristiques physico-chimiques des eaux d’alimentation de la ville de Biskra. Pratique de la coloration. Courrier du savoir, 6:53.
[30] El Ouedzhiri K., El Oualtia, El Ouchy M., Zerrouq F., Ouazzani haldi F., El Ouali Lalami A. (2014). Risques sanitaires liés aux composés chimiques contenus dans l’eau de boisson dans la ville de Fès: cas des ions nitrates et nitrites. J. Mater: Environ Sci., 5 (S1): 2284-2292.
Cite This Article
  • APA Style

    Narcisse Malanda, Laurent Matini, Paul Louzolo-Kimbembe, Pregidi Mbayi, Bernard Mabiala. (2019). State of Play on the Physicochemical Quality of Waters Stored in Concrete Tank Buried Under Wet and Polluted Soil: The Case of the City of Pointe-Noire (CONGO). American Journal of Environmental Protection, 7(6), 84-98. https://doi.org/10.11648/j.ajep.20180706.13

    Copy | Download

    ACS Style

    Narcisse Malanda; Laurent Matini; Paul Louzolo-Kimbembe; Pregidi Mbayi; Bernard Mabiala. State of Play on the Physicochemical Quality of Waters Stored in Concrete Tank Buried Under Wet and Polluted Soil: The Case of the City of Pointe-Noire (CONGO). Am. J. Environ. Prot. 2019, 7(6), 84-98. doi: 10.11648/j.ajep.20180706.13

    Copy | Download

    AMA Style

    Narcisse Malanda, Laurent Matini, Paul Louzolo-Kimbembe, Pregidi Mbayi, Bernard Mabiala. State of Play on the Physicochemical Quality of Waters Stored in Concrete Tank Buried Under Wet and Polluted Soil: The Case of the City of Pointe-Noire (CONGO). Am J Environ Prot. 2019;7(6):84-98. doi: 10.11648/j.ajep.20180706.13

    Copy | Download

  • @article{10.11648/j.ajep.20180706.13,
      author = {Narcisse Malanda and Laurent Matini and Paul Louzolo-Kimbembe and Pregidi Mbayi and Bernard Mabiala},
      title = {State of Play on the Physicochemical Quality of Waters Stored in Concrete Tank Buried Under Wet and Polluted Soil: The Case of the City of Pointe-Noire (CONGO)},
      journal = {American Journal of Environmental Protection},
      volume = {7},
      number = {6},
      pages = {84-98},
      doi = {10.11648/j.ajep.20180706.13},
      url = {https://doi.org/10.11648/j.ajep.20180706.13},
      eprint = {https://download.sciencepg.com/pdf/10.11648.j.ajep.20180706.13},
      abstract = {The problem of water supply from the public distribution network is still very acute in many cities in developing countries. The intermittent supply of water is forcing some households to build underground tanks of reinforced concrete to store domestic water. This work shows the problem of sustainability of water storage tanks made of concrete, in an aggressive environment but also especially the physicochemical quality of water stored in. The methodological approach chosen is based first of all on the physicochemical analysis of the water stored in these tanks. Indeed, the reliability of tanks, which reflected in their impermeability overlooked external environment, has a direct impact on the quality of stored water and therefore the use that is made daily. In this context, the results of the physicochemical measurements carried out, the comparison of the water coming out of the treatment plant of the National Water Distribution Company (SNDE), made it possible to highlight indices of pollution in the stored waters contained in the buried tanks.. Some samples of stored water, about 42.10%; which poses a public health problem. These results have clearly demonstrated the porous nature of the concrete chosen as the base material used for the construction of said tanks. Thus, anthropogenic pollution is evoked, which is confirmed by the high levels of physicochemical parameters measured in samples RE01, RE02, RE03, RE04, RE04, RE05, RE10, RE11 and RE12. In addition, 57.9% of these stored waters have low mineralization. These are acceptable as drinking water (RE06, RE07, RE08, RE09, RE13, RE14, RE15, RE16, RE17, RE18 and RE19). These waters identified as such must be subject to specific treatment and time monitoring. These results were obtained during dry season. During this period, there is drawdown of ground water. In rainy season, ground water is enhanced and exchanges are more important.},
     year = {2019}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - State of Play on the Physicochemical Quality of Waters Stored in Concrete Tank Buried Under Wet and Polluted Soil: The Case of the City of Pointe-Noire (CONGO)
    AU  - Narcisse Malanda
    AU  - Laurent Matini
    AU  - Paul Louzolo-Kimbembe
    AU  - Pregidi Mbayi
    AU  - Bernard Mabiala
    Y1  - 2019/01/10
    PY  - 2019
    N1  - https://doi.org/10.11648/j.ajep.20180706.13
    DO  - 10.11648/j.ajep.20180706.13
    T2  - American Journal of Environmental Protection
    JF  - American Journal of Environmental Protection
    JO  - American Journal of Environmental Protection
    SP  - 84
    EP  - 98
    PB  - Science Publishing Group
    SN  - 2328-5699
    UR  - https://doi.org/10.11648/j.ajep.20180706.13
    AB  - The problem of water supply from the public distribution network is still very acute in many cities in developing countries. The intermittent supply of water is forcing some households to build underground tanks of reinforced concrete to store domestic water. This work shows the problem of sustainability of water storage tanks made of concrete, in an aggressive environment but also especially the physicochemical quality of water stored in. The methodological approach chosen is based first of all on the physicochemical analysis of the water stored in these tanks. Indeed, the reliability of tanks, which reflected in their impermeability overlooked external environment, has a direct impact on the quality of stored water and therefore the use that is made daily. In this context, the results of the physicochemical measurements carried out, the comparison of the water coming out of the treatment plant of the National Water Distribution Company (SNDE), made it possible to highlight indices of pollution in the stored waters contained in the buried tanks.. Some samples of stored water, about 42.10%; which poses a public health problem. These results have clearly demonstrated the porous nature of the concrete chosen as the base material used for the construction of said tanks. Thus, anthropogenic pollution is evoked, which is confirmed by the high levels of physicochemical parameters measured in samples RE01, RE02, RE03, RE04, RE04, RE05, RE10, RE11 and RE12. In addition, 57.9% of these stored waters have low mineralization. These are acceptable as drinking water (RE06, RE07, RE08, RE09, RE13, RE14, RE15, RE16, RE17, RE18 and RE19). These waters identified as such must be subject to specific treatment and time monitoring. These results were obtained during dry season. During this period, there is drawdown of ground water. In rainy season, ground water is enhanced and exchanges are more important.
    VL  - 7
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Mechanical, Energy and Engineering Laboratory, Higher National Polytechnic School, Marien Ngouabi University, Brazzaville, Congo

  • Department of Chemistry, Higher Normal School, Marien Ngouabi University, Brazzaville, Congo

  • Department of Chemistry, Higher Normal School, Marien Ngouabi University, Brazzaville, Congo

  • Mechanical, Energy and Engineering Laboratory, Higher National Polytechnic School, Marien Ngouabi University, Brazzaville, Congo

  • Mechanical, Energy and Engineering Laboratory, Higher National Polytechnic School, Marien Ngouabi University, Brazzaville, Congo