American Journal of Environmental Protection

| Peer-Reviewed |

Supporting Capacity-Building Project Characteristics Test of Zhoushan Multi-Terminal HVDC Flexible Demonstration Project

Received: May 15, 2018    Accepted: Jun. 14, 2018    Published: Jul. 11, 2018
Views:       Downloads:

Share This Article

Abstract

In this paper, a flexible Zhoushan multiterminal HVDC test demonstration projects supporting capacity-building project for the study, the DC cables through the flexible testing ground field measurements of its surrounding environment, the DC cables of a flexible environment affect the characteristics of the test site. The results show: the project on the surrounding environment has little effect of electromagnetic radiation, which affect the field strength generated by the project on the environment is negligible, the project generated frequency electric field, power frequency magnetic fields, DC magnetic field, radio interference strength, noise are smaller than the corresponding standard limits.

DOI 10.11648/j.ajep.20180702.11
Published in American Journal of Environmental Protection ( Volume 7, Issue 2, April 2018 )
Page(s) 23-28
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Flexible DC Transmission, Environmental Impact, Electric Field, Magnetic Filed, Radio Interference, Noise

References
[1] Xiao Hao, Zhai Zeyang, Gao Guige, Zeng Xianwen. Analysis of key technologies and prospects of flexible HVDC transmission [J]. Electrical Engineering and Energy Efficient Management Technology, 2015, 1(17):32-38.
[2] LIU Ye, HE Weiguo, BAO Hailong, Research on flexible DC transmission technology and its application prospects [J]. 2008, 25(1):6-9.
[3] Liu Bing, Lou Jiangjun, Han Haihong, et al. Electromagnetic environment analysis of flexible HVDC transmission system [J]. High Voltage Technology, 2009, 35(11):2747-2752.
[4] Su Minghong, Sun Wei, Zhao Gang, et al. Calculation and optimization of electric field distribution of UHV bipolar DC voltage generator [J] 2008, 44(5):402-405.
[5] Guodian Environmental Protection Research Institute, «Special Report on the Influence of Electromagnetic Environment on the Supporting Test Capability Project of Zhoushan Duplex Flexible HVDC Transmission Demonstration Project» January 2013.
[6] People's Republic of China Environmental Protection Standards, HJ 681-2013, Electromagnetic environmental monitoring method for AC electric power transmission and distribution project, November 2013.
[7] People's Republic of China Environmental Protection Standards, GB 15707-1995, Limits of radio interference from AC high voltage overhead power transmisslon lines, September 1995.
[8] People's Republic of China Environmental Protection Standards, GB 8702-2014, Controlling limits for electromagnetic environment, September 2014.
[9] People's Republic of China Environmental Protection Standards, GB 12348-2008, Emisson standard for industrial enterprises noise at boundary, August 2008.
[10] People's Republic of China Environmental Protection Standards, GB 3096-2008, Environmental quality standard for noise, August 2008.
Cite This Article
  • APA Style

    Guilong Liu, Ying Zhu, Siquan Lu, Youpeng Hong, Jian Wu. (2018). Supporting Capacity-Building Project Characteristics Test of Zhoushan Multi-Terminal HVDC Flexible Demonstration Project. American Journal of Environmental Protection, 7(2), 23-28. https://doi.org/10.11648/j.ajep.20180702.11

    Copy | Download

    ACS Style

    Guilong Liu; Ying Zhu; Siquan Lu; Youpeng Hong; Jian Wu. Supporting Capacity-Building Project Characteristics Test of Zhoushan Multi-Terminal HVDC Flexible Demonstration Project. Am. J. Environ. Prot. 2018, 7(2), 23-28. doi: 10.11648/j.ajep.20180702.11

    Copy | Download

    AMA Style

    Guilong Liu, Ying Zhu, Siquan Lu, Youpeng Hong, Jian Wu. Supporting Capacity-Building Project Characteristics Test of Zhoushan Multi-Terminal HVDC Flexible Demonstration Project. Am J Environ Prot. 2018;7(2):23-28. doi: 10.11648/j.ajep.20180702.11

    Copy | Download

  • @article{10.11648/j.ajep.20180702.11,
      author = {Guilong Liu and Ying Zhu and Siquan Lu and Youpeng Hong and Jian Wu},
      title = {Supporting Capacity-Building Project Characteristics Test of Zhoushan Multi-Terminal HVDC Flexible Demonstration Project},
      journal = {American Journal of Environmental Protection},
      volume = {7},
      number = {2},
      pages = {23-28},
      doi = {10.11648/j.ajep.20180702.11},
      url = {https://doi.org/10.11648/j.ajep.20180702.11},
      eprint = {https://download.sciencepg.com/pdf/10.11648.j.ajep.20180702.11},
      abstract = {In this paper, a flexible Zhoushan multiterminal HVDC test demonstration projects supporting capacity-building project for the study, the DC cables through the flexible testing ground field measurements of its surrounding environment, the DC cables of a flexible environment affect the characteristics of the test site. The results show: the project on the surrounding environment has little effect of electromagnetic radiation, which affect the field strength generated by the project on the environment is negligible, the project generated frequency electric field, power frequency magnetic fields, DC magnetic field, radio interference strength, noise are smaller than the corresponding standard limits.},
     year = {2018}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Supporting Capacity-Building Project Characteristics Test of Zhoushan Multi-Terminal HVDC Flexible Demonstration Project
    AU  - Guilong Liu
    AU  - Ying Zhu
    AU  - Siquan Lu
    AU  - Youpeng Hong
    AU  - Jian Wu
    Y1  - 2018/07/11
    PY  - 2018
    N1  - https://doi.org/10.11648/j.ajep.20180702.11
    DO  - 10.11648/j.ajep.20180702.11
    T2  - American Journal of Environmental Protection
    JF  - American Journal of Environmental Protection
    JO  - American Journal of Environmental Protection
    SP  - 23
    EP  - 28
    PB  - Science Publishing Group
    SN  - 2328-5699
    UR  - https://doi.org/10.11648/j.ajep.20180702.11
    AB  - In this paper, a flexible Zhoushan multiterminal HVDC test demonstration projects supporting capacity-building project for the study, the DC cables through the flexible testing ground field measurements of its surrounding environment, the DC cables of a flexible environment affect the characteristics of the test site. The results show: the project on the surrounding environment has little effect of electromagnetic radiation, which affect the field strength generated by the project on the environment is negligible, the project generated frequency electric field, power frequency magnetic fields, DC magnetic field, radio interference strength, noise are smaller than the corresponding standard limits.
    VL  - 7
    IS  - 2
    ER  - 

    Copy | Download

Author Information
  • Zhejiang Provincial Environmental Radiation Monitoring Center, Zhejiang Province Key Laboratory of Environmental Radiation Safety Monitoring, Hangzhou, China

  • Zhejiang Provincial Environmental Radiation Monitoring Center, Zhejiang Province Key Laboratory of Environmental Radiation Safety Monitoring, Hangzhou, China

  • Zhejiang Provincial Environmental Radiation Monitoring Center, Zhejiang Province Key Laboratory of Environmental Radiation Safety Monitoring, Hangzhou, China

  • Zhejiang Provincial Environmental Radiation Monitoring Center, Zhejiang Province Key Laboratory of Environmental Radiation Safety Monitoring, Hangzhou, China

  • Zhejiang Provincial Environmental Radiation Monitoring Center, Zhejiang Province Key Laboratory of Environmental Radiation Safety Monitoring, Hangzhou, China

  • Section