The objective of the work is to propose a model that can analyse the conformity of a stadium, sports field or other sports facility to Italian safety norms. The model serves in particular to analyse the adequacy of the facility ‘safety plan’ in terms of its definition of the stages, procedures and times for evacuation of the facility. The model is structured in modular form, beginning with an analysis of the conformity of the sports facility to the applicable norms. This first stage applies a series of purpose-developed checklists to describe the facility as defined by Ministerial Decrees 18/03/1996 and 06/06/2005. Following this, the facility is characterized in terms of its location, dimensions and structural type. The next stages are: i) the analysis and estimation of the evacuation times, on the basis of the information previously gathered on the facilities; ii) the evaluation of conformity with the safety plan for the particular facility, applying the results from the previous steps. The proposed framework can be used as an instrument in support of decision-making for improvement in the safety levels of the sports facility, through augmenting the effectiveness of procedures and equipment, while also considering the economic implications of the potential improvements.
Published in | American Journal of Sports Science (Volume 4, Issue 4) |
DOI | 10.11648/j.ajss.20160404.12 |
Page(s) | 69-76 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2016. Published by Science Publishing Group |
Safety, Framework, Sports Facilities, Evacuation, Italian Safety Norms
[1] | Ministerial decree of 18 March 1996, Safety norms for the construction and operation of sports facilities, amended and supplemented by Ministerial decree of 6 June 2005 decree 06/06/2005. |
[2] | Italian National Olympic Committee norms for sports facilities. |
[3] | Ministerial decree of 10 March 1998, General criteria for fire-prevention safety and the management of emergencies in workplaces. |
[4] | Musumarra L., La gestione della sicurezza negli impianti sportivi. |
[5] | Italian Football Federation system and security regulations. |
[6] | La Malfa A., Analisi delle condizioni di sicurezza delle vie di esodo secondo l’approccio ingegneristico, in proceedings of Fire Safety Engineering: un nuovo approccio alla prevenzione incendi, INFORMA, Rome, 29 November 2001. |
[7] | Bianchi R., Progetto & prodotto, in Impianti Sportivi. |
[8] | Lucantoni A., La gestione delle manifestazione con presenza di public, presented as part of a course on safety in sports facilities, Rome. |
[9] | Vigne G., Marsella S., L’approccio ingegneristico alla sicurezza antincendio nel sistema normativo italiano, in Antincendio, EPC Rome, 2001. |
[10] | Bruno A., Norme di riferimento: aspetti che caratterizzano gli impianti sportive, presented as part of a course on safety in sports facilities, Rome. |
[11] | Bruno A., Corso, Rischi specifici, presented as part of a course on safety in sports facilities, Rome. |
[12] | Di Sivo M., La gestione della sicurezza degli impianti sportivi. |
[13] | Editrice il campo, Nuove tecnologie per la sicurezza negli stadi, http.//sportindustry.com, last consulted 31/01/2015. |
[14] | Antoniotti M., Guida ai piani di sicurezza. |
[15] | Di Nenno P. J. (ed.) The SFPE Handbook of Fire Protection Engineering, Second Edition, Society of Fire Protection Engineers, Bethesda, 1995. |
[16] | Marzotti L., Approccio ingegneristico alla sicurezza antincendio, http://www.vigilfuoco.it/aspx/ReturnDocument.aspx?IdDocumento=47, last consulted 31/01/2015. |
APA Style
Massimo de Falco, Donato Di Stasi, Carmine Novellino. (2016). Sports Facility Safety Plans: A Framework for Evaluation of Evacuation Times. American Journal of Sports Science, 4(4), 69-76. https://doi.org/10.11648/j.ajss.20160404.12
ACS Style
Massimo de Falco; Donato Di Stasi; Carmine Novellino. Sports Facility Safety Plans: A Framework for Evaluation of Evacuation Times. Am. J. Sports Sci. 2016, 4(4), 69-76. doi: 10.11648/j.ajss.20160404.12
AMA Style
Massimo de Falco, Donato Di Stasi, Carmine Novellino. Sports Facility Safety Plans: A Framework for Evaluation of Evacuation Times. Am J Sports Sci. 2016;4(4):69-76. doi: 10.11648/j.ajss.20160404.12
@article{10.11648/j.ajss.20160404.12, author = {Massimo de Falco and Donato Di Stasi and Carmine Novellino}, title = {Sports Facility Safety Plans: A Framework for Evaluation of Evacuation Times}, journal = {American Journal of Sports Science}, volume = {4}, number = {4}, pages = {69-76}, doi = {10.11648/j.ajss.20160404.12}, url = {https://doi.org/10.11648/j.ajss.20160404.12}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajss.20160404.12}, abstract = {The objective of the work is to propose a model that can analyse the conformity of a stadium, sports field or other sports facility to Italian safety norms. The model serves in particular to analyse the adequacy of the facility ‘safety plan’ in terms of its definition of the stages, procedures and times for evacuation of the facility. The model is structured in modular form, beginning with an analysis of the conformity of the sports facility to the applicable norms. This first stage applies a series of purpose-developed checklists to describe the facility as defined by Ministerial Decrees 18/03/1996 and 06/06/2005. Following this, the facility is characterized in terms of its location, dimensions and structural type. The next stages are: i) the analysis and estimation of the evacuation times, on the basis of the information previously gathered on the facilities; ii) the evaluation of conformity with the safety plan for the particular facility, applying the results from the previous steps. The proposed framework can be used as an instrument in support of decision-making for improvement in the safety levels of the sports facility, through augmenting the effectiveness of procedures and equipment, while also considering the economic implications of the potential improvements.}, year = {2016} }
TY - JOUR T1 - Sports Facility Safety Plans: A Framework for Evaluation of Evacuation Times AU - Massimo de Falco AU - Donato Di Stasi AU - Carmine Novellino Y1 - 2016/06/18 PY - 2016 N1 - https://doi.org/10.11648/j.ajss.20160404.12 DO - 10.11648/j.ajss.20160404.12 T2 - American Journal of Sports Science JF - American Journal of Sports Science JO - American Journal of Sports Science SP - 69 EP - 76 PB - Science Publishing Group SN - 2330-8540 UR - https://doi.org/10.11648/j.ajss.20160404.12 AB - The objective of the work is to propose a model that can analyse the conformity of a stadium, sports field or other sports facility to Italian safety norms. The model serves in particular to analyse the adequacy of the facility ‘safety plan’ in terms of its definition of the stages, procedures and times for evacuation of the facility. The model is structured in modular form, beginning with an analysis of the conformity of the sports facility to the applicable norms. This first stage applies a series of purpose-developed checklists to describe the facility as defined by Ministerial Decrees 18/03/1996 and 06/06/2005. Following this, the facility is characterized in terms of its location, dimensions and structural type. The next stages are: i) the analysis and estimation of the evacuation times, on the basis of the information previously gathered on the facilities; ii) the evaluation of conformity with the safety plan for the particular facility, applying the results from the previous steps. The proposed framework can be used as an instrument in support of decision-making for improvement in the safety levels of the sports facility, through augmenting the effectiveness of procedures and equipment, while also considering the economic implications of the potential improvements. VL - 4 IS - 4 ER -