| Peer-Reviewed

Analysis and Comparison of Two Stage and Single Stage Operational Amplifiers Using 0.18µm Technology

Received: 24 November 2022    Accepted: 9 January 2023    Published: 31 January 2023
Views:       Downloads:
Abstract

Operational amplifier exists in many numbers of configurations. The there are many types of the Operational amplifiers. These are: two stage, single stage, three stage and multistage amplifiers. Identifying the better op amp is important to get better application. The better op amp will be selected by considering the performance parameters (DC Gain, Slew Rate, Power Dissipation, etc.) of op amp. In project work a two stage cmos and single stage CMOS operational has been compared and contrasted based on values of their performance parameters by using 0.18µm CMOS technology and the same power supply (5V). Based on these values, By comparing the performance parameters single stage CMOS op amp is more stable and operate longer duration of time than two stage cmos op amp with small energy loss; while two stage op amp produces the output which is twice larger than single stage op amp, and also the noise in the output of two stage op amp is less than single stage op amp. So to get more output it is better to use two stage op amps. By results and reasons suitable choices for high gain and high performance applications are two stage topologies.

Published in American Journal of Physics and Applications (Volume 10, Issue 6)
DOI 10.11648/j.ajpa.20221006.11
Page(s) 72-75
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Single Stage CMOS Op Amp, two Stage Op Amp, Gain, Phase Margin

References
[1] W. T. Holman, J. A. Connelly, J. O. Perez, “A Low Noise Operational Amplifier in a1.2µM Digital Technology”, IEEE Journal 2007.
[2] Ramakant A. Gaikwad, “OP-Amps and Linear integerated circuits”, Fourth Edition.
[3] Ming-Dou Ker; Jung-Sheng Chen, “Impact of MOSFET Gate-Oxide Reliability on CMOS Operational Amplifier in a 130- nm Low-Voltage Process”, IEEE Journal 2008.
[4] Amanna Yadav, “A Review paper on design and synthesis of two stage CMOS OPAMP”, International Journal of Advances in Engineering & technology, Vol. 2, Issue 1, pp. 677-688, Jan 2012.
[5] Hiyuan Li; Jianguo Ma; Mingyan Yu; Yizheng Ye “Low noise operational amplifier design with current driving bulk in 0.25μm CMOS technology”, IEEE Conference 2005, Pages: 630-634/
[6] Vincence, V. C.; Galup-Montoro, C.; Schneider, M. C., “Low-voltage class AB operational amplifier”, IEEE Conference 2001, Page(s): 207-211.
[7] R. Jacob Baker, Harry W. Liand David E. Boyce, “CMOS circuit design, layout and simulation”, IEEE Press series on microelectronics systems, Prentice Hall of India Private Limited, 2014.
[8] Hitesh Modi, Nilesh D. Patel, “Design And Simulation Of Two Stage OTA Using 180nm And 350nm Technology”, International Journal of Engineering and Advanced Technology (IJEAT), ISSN: 2249-8958, Volume-2, Issue-3, February 2013.
[9] B. Razavi (2001). Design of analog CMOS integrated circuits, Tata Mc GrawHill Edition.
[10] M Jasmine, (2004). Design and analysis of telescopic operational amplifier.
[11] Kush Gulati and Hae-Seung Lee, (December 1998). A High-Swing, HighPerformance CMOS Telescopic Operational Amplifier, IEEE Journal of SolidState Circuits, 33, No. 12.
[12] Kush Gulati, H-S. Lee, (1998). A ±2.45V-Swing CMOS Telescopic Operational Amplifier, Massachusetts Institute of Technology, Cambridge, MA IEEE.
[13] M. Tan and Q. Zhou, “A two-stage amplifier with active miller compensation,” 2011 IEEE International Conference on Anti-Counterfeiting, Security and Identification, pp. 201–204, 2011.
[14] F. Rahmani, "Electric Vehicle Charger based on DC/DC Converter Topology," International Journal of Engineering Science, vol. 18879, 2018.
[15] S. Dolatiary, J. Rahmani, and Z. Khalilzad, "Optimum location of DG units considering operation conditions," 2018.
Cite This Article
  • APA Style

    Tsegaye Menberu. (2023). Analysis and Comparison of Two Stage and Single Stage Operational Amplifiers Using 0.18µm Technology. American Journal of Physics and Applications, 10(6), 72-75. https://doi.org/10.11648/j.ajpa.20221006.11

    Copy | Download

    ACS Style

    Tsegaye Menberu. Analysis and Comparison of Two Stage and Single Stage Operational Amplifiers Using 0.18µm Technology. Am. J. Phys. Appl. 2023, 10(6), 72-75. doi: 10.11648/j.ajpa.20221006.11

    Copy | Download

    AMA Style

    Tsegaye Menberu. Analysis and Comparison of Two Stage and Single Stage Operational Amplifiers Using 0.18µm Technology. Am J Phys Appl. 2023;10(6):72-75. doi: 10.11648/j.ajpa.20221006.11

    Copy | Download

  • @article{10.11648/j.ajpa.20221006.11,
      author = {Tsegaye Menberu},
      title = {Analysis and Comparison of Two Stage and Single Stage Operational Amplifiers Using 0.18µm Technology},
      journal = {American Journal of Physics and Applications},
      volume = {10},
      number = {6},
      pages = {72-75},
      doi = {10.11648/j.ajpa.20221006.11},
      url = {https://doi.org/10.11648/j.ajpa.20221006.11},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajpa.20221006.11},
      abstract = {Operational amplifier exists in many numbers of configurations. The there are many types of the Operational amplifiers. These are: two stage, single stage, three stage and multistage amplifiers. Identifying the better op amp is important to get better application. The better op amp will be selected by considering the performance parameters (DC Gain, Slew Rate, Power Dissipation, etc.) of op amp. In project work a two stage cmos and single stage CMOS operational has been compared and contrasted based on values of their performance parameters by using 0.18µm CMOS technology and the same power supply (5V). Based on these values, By comparing the performance parameters single stage CMOS op amp is more stable and operate longer duration of time than two stage cmos op amp with small energy loss; while two stage op amp produces the output which is twice larger than single stage op amp, and also the noise in the output of two stage op amp is less than single stage op amp. So to get more output it is better to use two stage op amps. By results and reasons suitable choices for high gain and high performance applications are two stage topologies.},
     year = {2023}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Analysis and Comparison of Two Stage and Single Stage Operational Amplifiers Using 0.18µm Technology
    AU  - Tsegaye Menberu
    Y1  - 2023/01/31
    PY  - 2023
    N1  - https://doi.org/10.11648/j.ajpa.20221006.11
    DO  - 10.11648/j.ajpa.20221006.11
    T2  - American Journal of Physics and Applications
    JF  - American Journal of Physics and Applications
    JO  - American Journal of Physics and Applications
    SP  - 72
    EP  - 75
    PB  - Science Publishing Group
    SN  - 2330-4308
    UR  - https://doi.org/10.11648/j.ajpa.20221006.11
    AB  - Operational amplifier exists in many numbers of configurations. The there are many types of the Operational amplifiers. These are: two stage, single stage, three stage and multistage amplifiers. Identifying the better op amp is important to get better application. The better op amp will be selected by considering the performance parameters (DC Gain, Slew Rate, Power Dissipation, etc.) of op amp. In project work a two stage cmos and single stage CMOS operational has been compared and contrasted based on values of their performance parameters by using 0.18µm CMOS technology and the same power supply (5V). Based on these values, By comparing the performance parameters single stage CMOS op amp is more stable and operate longer duration of time than two stage cmos op amp with small energy loss; while two stage op amp produces the output which is twice larger than single stage op amp, and also the noise in the output of two stage op amp is less than single stage op amp. So to get more output it is better to use two stage op amps. By results and reasons suitable choices for high gain and high performance applications are two stage topologies.
    VL  - 10
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Department of Physics, College of natural and Computational Science, Wolkite University, Wolkite, Ethiopia

  • Sections