The objective of this study is to evaluate the impact of orientation on the thermal comfort of bioclimatic buildings in general, and in particular those built with compressed earth blocks. A first experimental study confirmed that compressed earth blocks have good thermal inertia, and made it possible to determine the number of annual hours of thermal comfort in the room. The results showed a thermal phase shift of 6 hours with a temperature difference of 10°C between the outside and the inside of the room, for an annual total of 4788 hours of comfort (54.65%) compared to 2158 hours of discomfort (49.80%), with a hygrothermal index (HIT) of 1.6 and an annual cooling requirement of 753.55 kWh. Subsequently, dynamic thermal simulations (DTS) carried out on different orientations made it possible to optimize the thermal comfort and energy consumption of the premises studied. The NORTHEAST and SOUTH-EAST orientation of the facades, with the two windows of the premises, made it possible to achieve 78.1% thermal comfort, or 6833 hours, a HIT of 0.5 and an annual power requirement of cooling of 523.78 kWh. Finally, similar work was carried out to propose optimal orientations for bioclimatic buildings in the three climatic zones of Burkina Faso.
Published in | Science Journal of Energy Engineering (Volume 12, Issue 4) |
DOI | 10.11648/j.sjee.20241204.14 |
Page(s) | 101-112 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2024. Published by Science Publishing Group |
Orientation, Bioclimatic, Thermal Comfort, Passive Methods, Hot and Dry Climate, Thermal Simulation
[1] | M. Mohammed, “Study and evaluation of the thermal comfort of public buildings: Case of the Department of Architecture of Tamda (Tizi-Ouzou) (in french).,” Mouloud Mammeri University of Tizi Ouzou, Algerie, 2012. |
[2] | A. Compaore, D. J. Bathiebo, and B. Zeghmati, “Modeling heat transfers in a building constructed with local materials in a dry tropical climate (in french).,” in 18èmes Journées Internationales de Thermique (JITH 2017), Monastir (Tunisie), 2017, pp. 1–11. |
[3] | M. Kabore, “Stakes of simulation for the study of energy performance of buildings in Sub-Saharan Africa (in french),” 2015. |
[4] | A. A. T. Ouedraogo, E. Malbila, N. Kagambega, and Y. K. David, “Comparative numerical and experimental studies of the tensile strengths of concrete incorporating recycled and natural aggregates,” 2023. |
[5] | N. Hadjadji, N. Toulan, and M. Dorra, “Impact of digital architecture: The impact of digital technology on ecological formations and its effect on determinants of identity and culture in architectural design,” J. Eng. Res., no. June, 2024, |
[6] | D. Y. K. Toguyeni, A. Lawane, F. Zoma, and G. Khamis, “Formulation of Compressed Earth Blocks Stabilized With Lime and Hibiscus Sabdariffa Fibres Showcasing Good Thermal and Mechanical Properties,” J. Mater. Sci. Surf. Eng., vol. 6, no. 4, pp. 817–824, 2018. |
[7] | E. Malbila, D. Y. K. Toguyeni, D. J. Bathiebo, and J. Koulidiati, “Hygrothermal behavior of two buildings constructed in cement bricks and cut laterite blocks,” Int. Conf. Energy, Environ. Econ. 11-13 December 2017, no. December, pp. 11–13, 2017. ISSN (Online): 2348-8956; |
[8] | E. Ouedraogo, O. Coulibaly, A. Ouedraogo, and A. Messan, “Mechanical and Thermophysical Properties of Cement and/or Paper (Cellulose) Stabilized Compressed Clay Bricks.,” J. Mater. Eng. Struct., vol. 2, no. 2, pp. 68–76, 2015. |
[9] | K. Toussakoe, E. Ouedraogo, K. B. Imbga, and A. Messan, “Caractérisation mécanique et thermo- physique de l ’ adobe utilisé dans la voûte nubienne Résumé,” vol. 19, no. 5, pp. 186–199, 2021. |
[10] | K. Toussakoe et al., “Prediction of Thermal Comfort from Operating Temperature and the Predicted Mean Vote / Predicted Percentage Dissatisfied (PMV / PPD) Indices in a Nubian Vault,” vol. 12, no. 1, pp. 9–16, 2023, |
[11] | A. Compaore, B. Ouedraogo, and H. Guengane, “Role of Local Building Materials on the Energy Behaviour of Habitats in Ouagadougou,” vol. 08, no. 02, pp. 63–72, 2017. |
[12] | M. Taleghani, M. Tenpierik, S. Kurvers, and A. Van Den Dobbelsteen, “A review into thermal comfort in buildings,” Renew. Sustain. Energy Rev., vol. 26, pp. 201–215, Oct. 2013, |
[13] | M. Bouzoualegh, “The effect of orientation on indoor thermal comfort in individual housing: case study of the 20 August 1955 neighborhood in Skikda (in french).,” Algerie, 2020. |
[14] | L. Gondian et al., “Evaluation of the influence of occupants on summer comfort: use of uncertainty and sensitivity analyses (in french).,” in Conférence IBPSA France – Bordeaux – 2018, 2018. |
[15] | B. Louafi and S. Abdou, “Impact of orientation on indoor thermal comfort in collective housing (in french).,” Sci. Technol. D, vol. N°32, Dé, pp. 33–40, 2010. |
[16] | D. Kiki, “Impact of orientation on indoor thermal comfort in collective housing.,” Université de Liège (Belgique), 2023. |
[17] | Y. Besbas, “‘Characterization of summer thermal comfort in patient rooms. Case of Biskra hospitals (in french)’.,” Université Mohamed Khider-Biskra, 2019. |
[18] | O. Mansouri, B. Fatiha, and B. Rafik, “Influence of envelope reflectivity on building energy demand and thermal comfort (in french).,” Nat. Technol., 2017. |
[19] | “National Meteorological Agency of Burkina Faso (NMA-BF).” Accessed: Aug. 15, 2024. [Online]. Available: |
[20] | A. Majumder, L. Canale, C. C. Mastino, A. Pacitto, A. Frattolillo, and M. D. Isola, “Thermal Characterization of Recycled Materials for Building Insulation,” 2021. |
[21] | K. Toussakoe, E. Ouedraogo, K. B. Imbga, and A. Messan, “Mechanical and thermo-physical characterization of the adobe used in the Nubian vault (in french).,” Afrique Sci., vol. 19, no. 5, pp. 186–199, 2021. |
[22] | A. W. Bruno, D. Gallipoli, H. Kallel, and U. Kingdom, “Manuscript accepted for publication in Journal of Building Engineering”. 2019. |
[23] | A. Lareba, E. Malbila, and D. Dabilgou, “Evolution of the Average Temperature of the Interior Atmosphere of a Habitable Cell Made of Foamed Concrete in Burkina Faso,” vol. 26, no. 2, pp. 11–24, 2022, |
APA Style
Maiga, A., Sagna, K., Toussakoe, K., Zoma, V., Ouedraogo, L. A., et al. (2024). Optimization of Thermal Comfort in Compressed Earth Block (CEB) Buildings in Burkina Faso. Science Journal of Energy Engineering, 12(4), 101-112. https://doi.org/10.11648/j.sjee.20241204.14
ACS Style
Maiga, A.; Sagna, K.; Toussakoe, K.; Zoma, V.; Ouedraogo, L. A., et al. Optimization of Thermal Comfort in Compressed Earth Block (CEB) Buildings in Burkina Faso. Sci. J. Energy Eng. 2024, 12(4), 101-112. doi: 10.11648/j.sjee.20241204.14
@article{10.11648/j.sjee.20241204.14, author = {Alidou Maiga and Koffi Sagna and Karim Toussakoe and Vincent Zoma and Lareba Adélaïde Ouedraogo and Sié Kam}, title = {Optimization of Thermal Comfort in Compressed Earth Block (CEB) Buildings in Burkina Faso}, journal = {Science Journal of Energy Engineering}, volume = {12}, number = {4}, pages = {101-112}, doi = {10.11648/j.sjee.20241204.14}, url = {https://doi.org/10.11648/j.sjee.20241204.14}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.sjee.20241204.14}, abstract = {The objective of this study is to evaluate the impact of orientation on the thermal comfort of bioclimatic buildings in general, and in particular those built with compressed earth blocks. A first experimental study confirmed that compressed earth blocks have good thermal inertia, and made it possible to determine the number of annual hours of thermal comfort in the room. The results showed a thermal phase shift of 6 hours with a temperature difference of 10°C between the outside and the inside of the room, for an annual total of 4788 hours of comfort (54.65%) compared to 2158 hours of discomfort (49.80%), with a hygrothermal index (HIT) of 1.6 and an annual cooling requirement of 753.55 kWh. Subsequently, dynamic thermal simulations (DTS) carried out on different orientations made it possible to optimize the thermal comfort and energy consumption of the premises studied. The NORTHEAST and SOUTH-EAST orientation of the facades, with the two windows of the premises, made it possible to achieve 78.1% thermal comfort, or 6833 hours, a HIT of 0.5 and an annual power requirement of cooling of 523.78 kWh. Finally, similar work was carried out to propose optimal orientations for bioclimatic buildings in the three climatic zones of Burkina Faso.}, year = {2024} }
TY - JOUR T1 - Optimization of Thermal Comfort in Compressed Earth Block (CEB) Buildings in Burkina Faso AU - Alidou Maiga AU - Koffi Sagna AU - Karim Toussakoe AU - Vincent Zoma AU - Lareba Adélaïde Ouedraogo AU - Sié Kam Y1 - 2024/12/19 PY - 2024 N1 - https://doi.org/10.11648/j.sjee.20241204.14 DO - 10.11648/j.sjee.20241204.14 T2 - Science Journal of Energy Engineering JF - Science Journal of Energy Engineering JO - Science Journal of Energy Engineering SP - 101 EP - 112 PB - Science Publishing Group SN - 2376-8126 UR - https://doi.org/10.11648/j.sjee.20241204.14 AB - The objective of this study is to evaluate the impact of orientation on the thermal comfort of bioclimatic buildings in general, and in particular those built with compressed earth blocks. A first experimental study confirmed that compressed earth blocks have good thermal inertia, and made it possible to determine the number of annual hours of thermal comfort in the room. The results showed a thermal phase shift of 6 hours with a temperature difference of 10°C between the outside and the inside of the room, for an annual total of 4788 hours of comfort (54.65%) compared to 2158 hours of discomfort (49.80%), with a hygrothermal index (HIT) of 1.6 and an annual cooling requirement of 753.55 kWh. Subsequently, dynamic thermal simulations (DTS) carried out on different orientations made it possible to optimize the thermal comfort and energy consumption of the premises studied. The NORTHEAST and SOUTH-EAST orientation of the facades, with the two windows of the premises, made it possible to achieve 78.1% thermal comfort, or 6833 hours, a HIT of 0.5 and an annual power requirement of cooling of 523.78 kWh. Finally, similar work was carried out to propose optimal orientations for bioclimatic buildings in the three climatic zones of Burkina Faso. VL - 12 IS - 4 ER -